The Tutorial has an example about "multiple instances", but the exemple gave me a doubt: what happens with the flow if the condition "Inspection ok?" is a "NO" in each one of the cases in paralel mode (None, All, One and Complex)?
Dear Silvana,
If the sub process is set to work as "None" in Bizagi's exit mode configuration, then there would be as many validations for the "Inspection OK" condition as there are sub process instances.
If the "No" sequence condition is met for each one of them, then all of these instances would be closed, and there would be no "Issue insurance policy" active task.
For the "All", "One", and "Complex" configuration, this condition would be validated just once (when using "All", this validation would be done when the last one of the sub process instances is finished, while when using "One" this validation would be done when the very first one of these sub process instances finishes).
For the sake of the example and tutorial, there is no modeling consideration for this scenario in which none of the vehicles' inspection has an Ok inspection, but off course this model could be enhanced too so that it includes such types of considerations.
We kindly invite you to check out our latest tutorials, which we have renewed in order to provide more examples and guide.
Dear Silvana,
If the sub process is set to work as "None" in Bizagi's exit mode configuration, then there would be as many validations for the "Inspection OK" condition as there are sub process instances.
If the "No" sequence condition is met for each one of them, then all of these instances would be closed, and there would be no "Issue insurance policy" active task.
For the "All", "One", and "Complex" configuration, this condition would be validated just once (when using "All", this validation would be done when the last one of the sub process instances is finished, while when using "One" this validation would be done when the very first one of these sub process instances finishes).
For the sake of the example and tutorial, there is no modeling consideration for this scenario in which none of the vehicles' inspection has an Ok inspection, but off course this model could be enhanced too so that it includes such types of considerations.
We kindly invite you to check out our latest tutorials, which we have renewed in order to provide more examples and guide.
Hello, I have a similar doubt, Dont know if create a new topic or continue here.
THanks this post i found document with the examples, but i have a doubt for example WCP 15 - Multiple Instances without a Priori Design-Time
Knowledge, How is the Event Create task working? Can you provide how should look like the inside of the subprocess? I have doubts how is the event link, I wil lappreciate some help regarding that.
thanks.
Dear Raciel,
In order to help you solve your doubts, we would like to know if you are talking about Bizagi Studio or Bizagi Modeler. In addition, tell us the version you have been working.